National Fire Protection 211 standards for Chimneys, Fireplaces,
Vents and Solid Fuel-Burning Appliances 2006 Edition
Level 1
Scope : Readily accessible
areas of chimney, structure, and flue; lack of obstruction or
combustible deposits in flue; basic appliances installation and
connection.
Degree of access required :
Readily accessible portions of chimney exterior and interior;
accessible portions of appliance and chimney connection
Circumstances: Annual
inspection is required by Section 13.2; during routine cleaning of
chimney flue; upon direct replacement of appliance with one similar
type, input rating, and efficiency.
Indications: For verification
of suitability of the chimney for continued service, under the same
conditions and with the same appliance or appliances.
Level 2
Scope: All subjects of a level
1 inspection; proper construction and condition of accessible
portions of the chimney structure and all enclosed flues; proper
clearances from combustibles in accessible locations; size and
suitability of flues for connected appliances.
Degree of access required: All
accessible portions of the chimney exterior and interior, including
areas within accessible attics, crawl spaces, and basements, and
accessible portions of the appliance and chimney connection;
includes inspection by video scanning or other means.
Circumstances: Upon addition
or removal of one or more connected appliances or replacement of
appliance with dissimilar type, input rating or, efficiency; prior to
relining or replacement of flue lining; upon sale or transfer of the
property; after operating malfunction or external event likely to
have caused damage to the chimney.
ndications: For verification
of suitability of the chimney for new or changed conditions of
service; Where level 1 inspection is not sufficient to determine
serviceability of the chimney.
Level 3
Scope: All subjects of Level 1
and level 2 inspection; proper construction and condition of
concealed portions of chimney structure and enclosed flues; proper
clearances from combustibles.
Degree of access Required:
External and internal portions of chimney, including concealed areas
of the building or chimney; includes removal of components of
building or chimney where necessary, but only as a necessity gain
access to areas that are the subject of the inspection.
Circumstances: Where necessary
for the investigation of an incident that has caused damage to the
chimney or building; Where hazard detected or suspected as the
result of a level 1 or level 2 inspection and cannot be fully
evaluated without access to concealed areas.
Indications: When construction
of all or part of chimney is deemed critical to its renewed or
continued use; required only for those areas that cannot be properly
evaluated by a level 1 or level 2 inspection.